Introduction Permafrost underlying the foundation was suspected due to cracks found in the garage floor. Three test holes were drilled and revealed loose silty-sand and gravel to depths of 35 feet. Two of the test holes were outside the house, while one was drilled in the garage using a mobile drill. The test holes were inconclusive as to the presence of frozen soil (permafrost). The underlying soils exhibited very loose characteristics during drilling, indicating less than desirable compaction of the soils. Loose soils may settle during an earthquake or other dynamic event. When PTF received the house, two additional permafrost exploration holes were drilled. These holes were located south of the southeast corner of the garage and midway along the west wall. These holes were drilled by Shannon and Wilson Inc. under contract to the Permafrost Technology Foundation. The holes were drilled to a depth of over 50 feet. No frozen soil was found to that depth, although the sampling spoon was noted to be "very cold to the touch." Once again the soils were found to be very loose throughout the entire depth of the drill hole. Because the house showed no sign of permafrost and settlement damage was minimal, it was decided to monitor the structure for a period of time to see if any settlement or danger signs of settlement occurred. When no evidence of settlement was found after a year of monitoring the structure, the decision was made to continue the monitoring to determine the ultimate stability of the foundation and to gain data on what can be expected at a site with such very loose soils at depth. Structure Description Level Measurements It should be noted, however, that when level measurement are this precise, that perturbations can and do occur. These small changes are due to the placement of the rod from one measurement set to the next. Often the rod had to be placed behind furniture, and it was impossible to determine if it was sitting on the same spot as the previous measurement or if an electrical cord or a magazine etc. happened to be under the rod (even the thickness of several sheets of paper will show up at this precision). There was also the possibility for a gross error in reading the rod, since the level had the standard three cross hairs (center, upper and lower) used for measuring distances in surveying. If the operator was inexperienced (student labor was used for these measurements), a reading could be made using either the upper or lower cross hair instead of the center one. This error would yield an elevation that was in error by several tens of millimeters to as much as a few inches. These errors however are readily discernible when the data is plotted as a function of time. Level data on the concrete slab floor in the basement was collected several times a year and accumulated for a period of six years. The level data plotted as a function of time are shown in the appendix of this report. Each measurement location is designated on the floor plan by a letter. Different groups of letters were plotted together on the charts to show relevant comparisons such as the south wall or the diagonal across the structure. In each chart, all levels are referenced to a single reference point "A". This allows the elevation of each point to be compared as a relative elevation on the floor plan with respect to point A. From this data, differential elevations between different parts of the floor can be easily seen and tracked with time. This system, however does not give information as to the absolute elevation of the house with respect to the ground outside, and therefore any elevation variation of point A is also reflected in all other points. Determining absolute elevations requires a stable surveyor's benchmark or other stable reference outside of the structure. At this location a nail was driven into a large tree to attempt to provide a stable reference, however this did not prove to be reliably stable. Nevertheless, the relative elevations allow differential settlement to be tracked, and that is the most important information for these studies. For perspective, a differential floor elevation of one to two inches (25 mm to 50 mm) is not noticeable to the unaided eye, and up to four inches (100 mm) over the distance across a normal room, although noticeable, is not an overly unpleasant condition with which to live. Temperature Measurement Thermistors are capable of measuring temperature to the nearest one thousandth of a °C. However, the nearest one tenth of a degree is probably satisfactory for our purposes for everything except the location of the actual freezing front. Thermistors are more accurate than thermocouples; however, they have the disadvantage of being more fragile, and they can drift a few thousands of a degree over time. To obtain the maximum accuracy, the strings must be calibrated in a reference bath both before and after their use. These thermistor strings were calibrated before placing them in the hole, but since once installed they are buried, it is impractical to remove them without destroying them, therefore the secondary calibration cannot be made. The temperatures, therefore, cannot be relied upon to more than about a tenth of a degree. Thermistors located at various depths allow us to track the temperatures at those depths to determine if the permafrost is getting deeper, remaining stable, or actually rising. The data also alerts us to any anomalies in temperature that may occur due to outside influences such as new construction nearby, landscaping modifications, or damage or deterioration of protective insulation. Since no permafrost was found at this location, the temperature data here is not as important as in sites underlain by permafrost. However, the temperature trends over the years of measurement are valuable data to be used for control and reference to other sites that do have permafrost. Geotechnical Exploration Results and Conclusions Loose soils can allow settlement due to a number of conditions: the increased load placed on the soil at the time of construction, increases in the soil moisture due to watering of the lawn or snow melt from the roof, additional loads from later construction, etc. Any of these can cause the soil to compact allowing the surface and anything sitting on it to subside. The subsidence normally occurs very slowly over several months or a few years causing a slow wracking of the structure. Subsidence in this house appears to be very slow, the maximum being 5/8 in. over nearly six years in the northeast corner. The garage appears to be moving somewhat more, with 1½ in. of elevation change occurring. However, the garage floor slab has risen with respect to the rest of the house by that much and appears to be somewhat cyclic suggesting a frost heave effect. The question then becomes one of will the house continue to subside or has it reached stability. Only continued long-term monitoring can answer this question. In any case, nothing in the data suggests that the settlement, if it does continue, will be anything but very slow making it easy to compensate for the elevation changes before any structural damage could occur. Loose soils also raise the concern of settlement during a dynamic event such as an earthquake. During the period over which the level measurements were made on this house there were 15 earthquakes over Richter 4.0. and, of those, one was 5.0 on Nov 1, 1992 and one was 6.2 on October 6, 1995. This last one was the most significant event, since it was not only the largest but also it was the shallowest at only 9 km below the surface. It was felt very strongly by residents of Fairbanks. However, reviewing the data on level measurements shows that no significant measurable settlement can be identified in our data during any of these events. This suggests that either settlement into the loose soils beneath the structure was not triggered by a dynamic event of this magnitude or that settlement into the loose soils was already complete before the Permafrost Technology Foundation started monitoring the structure. These circumstances and observations do not preclude the possibility of settlement during a more severe earthquake or other type of dynamic event. Bibliography of References ASHRAE 1989. Handbook of Fundamentals, American
Society of Heating, Refrigeration, and Air-Conditioning Engineers, Inc.,
1791 Tullie Circle, N.E., Atlanta GA. Buska, J.S. and J.B. Johnson 1988. "Frost Heave
Forces on H and Pipe Foundation Piles." Proceedings of the Fifth International
Permafrost Conference, Trondheim, Norway, pp. 1039-1044. Chamberlain, E.J. 1988. "A New Freezing Test for
Determining Frost Susceptibility," Proceedings of the Fifth International
Permafrost Conference, Trondheim, Norway, pp. 1045-1050. Danyluk, L.S. 1986. Stabilization of Fine-Grained
Soil for Road and Airfield Construction, AKDOT/PF Report AKÄRDÄ86-30. Esch D.C. 1986. "Insulation Performance Beneath
Roads and Airfields in Alaska," Proceedings of the 4th Intl Cold Regions
Specialty Conference, Anchorage, AK. ASCE, 345 E. 47th. St. New York
City, NY 10017-2398. Esch D.C. 1988. "Embankment Case Histories on
Permafrost," Embankment Design and Construction in Cold Regions. American
Society of Civil Engineers, 345 East 47th St., New York, NY 10017-2398.
Farouki, O.T. 1985. "Ground Thermal Properties" Thermal Design Considerations
in Frozen Ground Engineering, ASCE, pp. 186-203. Forland K.S., T. Førland and S.K. Ratkje 1988,
"Frost Heave," Proceedings of the Fifth International Permafrost Conference,
Trondheim, Norway, pp. 344 -348. Freitag D. and T. McFadden 1997. Introduction
to Cold Regions Engineering. ASCE Press. American Society for Civil
Engineers New York City, NY. ISBN 0-7844-0006-7 Hartman, C.W. and P.R. Johnson 1978, Environmental
Atlas of Alaska, Univ. of Alaska Fairbanks, Fairbanks, AK. Johnson, P.R. 1971. Empirical Heat Transfer Rates of Small Long and Balch Thermal Piles and Thermal Convective Loops, Institute of Arctic Environmental Engineering, University of Alaska Fairbanks. Report 7102. Johnston G.H., Editor 1981. Permafrost Engineering
Design and Construction, John Wiley and Sons, New York. Kersten M.S. 1949. Thermal Properties of Soils.
University of Minn., Engineering Experiment Station, Bull. 28. Kinney T.C. and K.A. Troost, 1984, "Thaw Strain
of Laboratory Compacted Frozen Gravel," Proceedings: 3rd Internation
Specialty Conf. on Cold Regions Engineering. Canadian Society for Civil
Engineering, Edmonton, Alberta, Canada. Krzewinski T.G., T.A. Hammer and G.G. Booth 1988.
"Foundation Considerations for Siting and Designing the Red Dog Mine
Mill Facilities on Permafrost." Proceedings of the Fifth International
Permafrost Conference, Trondheim, Norway. pp. 955-960. Linell, K.A. and C.W. Kaplar, 1966. "Description
and Classification of Frozen Soils." Proc. International Conference
on Permafrost (1963) Lafayette IN. U.S. National Academy of Sciences,
Publ. 1287. pp. 481-487. Lovell C.W. 1983. "Frost Susceptibility of Soils"
Proceedings of the Fourth International Permafrost Conference, Fairbanks,
Alaska. pp. 735-739. Maksimjak R.V., S.S. Vyalov and A.A. Chapaev 1983.
"Methods for Determining the Long-Term Strength of Frozen Soils," Proceedings
of the Fourth International Permafrost Conference, Fairbanks, Alaska,
pp. 783-786. McFadden, T. and F.L. Bennett 1991. Construction
in Cold Regions. John Wiley and Sons Inc, New York City, NY. 615 Pgs.
ISBN 0-471-52503-0. Nixon, J.F. 1986. "Pipeline Frost Heave Predictions
Using a 2-D Thermal Model." in Andersland, O.B. and F.H. Sayles, eds.,
Research on Transportation Facilities in Cold Regions, Proceedings,
American Society of Civil Engineers, Boston, October 27, 1986, pp. 67-82. Penner, E. and C.B. Crawford 1983. Frost Action
and Foundations. National Research Council of Canada, Div. of Building
Research. DBR No. 1090, Ottawa, Canada. Rice, E.F. 1982. Building in the North. University
of Alaska Fairbanks, Fairbanks, AK. Rice, E.F. and K.E. Walker 1983. "Introduction
to Cold Regions Engineering." U.S. Army Cold Regions Research and Engineering
Laboratory, Hanover, NH. Internal Report #808. Smith, D.W. Editor 1986. Cold Climate Utilities Manual. Canadian Society for Civil Engineering, 2050 Mansfield St. Montreal, Quebec, Canada, H3A 1Z2. AppendixBore Hole Logs |